Hantek1008B
Cost-effective 8 channels oscilloscope for vehicle testing; 2.4MSa/s, 12bits; DAQ card function; 8 channels programmable generator which can analog signals of crankshaft, camshaft etc.
Ⅴ Feature
Highly efficient and cost-effective; 8 channels oscilloscope for vehicle testing; 2.4MSa/s real time sampling rate, 12bit vertical resolution; DAQ card function; 8 channels programmable generator which can analog signals of crankshaft, camshaft etc.
1) Vehicle Testing
- First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition
- Ignition: primary and secondary
- Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
- Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
- Performer: Petrol/Diesel
- Starter and charging circuits
2) Oscilloscope
- 8 channels oscilloscope, 2.4MSa/s real time sampling rate
- 12 bits vertical resolution, spectrum analysis function
3) Programmable Generator
- 8 channels programmable generator
- Can analog signals of crankshaft, camshaft etc.
4) Others
- USB 2.0 interface plug and play, and no need extra power supply;
- More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;
- Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7;
| Model | Hantek1008 |
| Oscilloscope Mode | |
| Vertical System | |
| Analog Channel | 8 |
| Input Impedance | Resistance: 1MΩ |
| Input Sensitivity | 10mV/div to 5V/div |
| Input Coupling | DC |
| Resolution | 12 bits |
| Horizontal System | |
| Memory Depth | 4K |
| Max. Input | 400V (DC+AC Peak) |
| Real-Time Sampling Rate | 2.4MSa/s |
| Time BaseRange | 1ns/div to 20000s/div(1-2-5sequences) |
| Time Base Precision | ±50ppm |
| Trigger System | |
| Time Base Range | 1ns/div to 20000s/div(1-2-5sequences) |
| Time Base Precision | ±50ppm |
| Trigger Source | CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8 |
| Trigger Mode | Edge |
| X-Y Mode | |
| X-Axis Input | CH1 |
| Y-Axis Input | CH2 |
| Cursors and Measurement | |
| Voltage Measurement | Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot |
| Time Measurement | Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
| Cursors Measurement | Horizontal ,Vertical, Track, Auto Measure Modes |
| Waveform Signal Process | +,- , x,÷, FFT, Invert |
| Voltage Range |
10mV
to 5V/div @ x 1 probe 100mV to 50V/div @ x 10 probe 10V to 5000V/div @ x 1000 probe 100V to 50000V/div @ x 10000 probe 200mV to 100V/div @ 20:1 |
| Current Range |
100mA
to50.0A/div @ CC65(20A) 1000mA to500.0A/div @ CC65(65A) 1A to100.0A/div @ CC650(60A) 1A to200.0A/div @CC1100(100A) 10A to2000.0A/div @CC1100(1100A) |
| FFT | Rectangular, Hanning, Hamming, Blackman Window |
| Math | Addition, subtraction, multiplication, division |
| Programmable Generator | |
| Channel | 8 |
| Output Level | LVTTL |
| Frequency Range | 0-250kHz |
| Interface | USB 2.0 |
| Power | No need extra power supply |
| Size & Weight | 185 x 150 x 27 (mm); 0.35kg |
Standard Accessories:
Optional Accessories:
|
Optional Power(HT310) |
LAN Module(HT312) |
|
6-Way Universal Breakout Leads(HT306) |
Auto High-Pressure Ignition Probe( HT25) |
|
20:1 Attenuator (HT201) |
Acupuncture Probe Set (HT307) |
|
Test leads(HT30A) |
Coil-on-Plug extension leads(HT308) |
|
Break Out Leads(HT301) |
AC/DC Current Clamp (CC-65) |
|
AC/DC Current Clamp( CC-650) |
AC/DC Current Clamp( CC-1100) |
|
Multimeter Probes(HT19) |
Large Dolphin/Gator Clips (HT18A) |
| Number | Attachments Title | Operating |
|---|---|---|
| 1 | Hantek1008 Software | Download |
| 2 | Hantek1008 Driver | Download |
| 3 | Hantek1008 Manual | Download |