Hantek6000BE Series
Bandwidth: 20MHz-200MHz; Sample Rate: 250MSa/s;
Excellent industrial design-the same anodised aluminium casing as iPad, which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.
Standard USBXI (TM) interface, easyly inserts into USBXI (TM) housing to make up a combination instrument.
Features
- Excellent industrial design-the same anodised aluminium casing as iPad, which is not only beautiful and tasteful but also greatly enhanced the hardness of aluminum alloy surface, and has good heat resistance and strong wearability.
- Standard USBXITM interface, easily inserts into USBXITM housing to make up a combination instrument.
- USB2.0 interface, no external power source required, easy to use.
- Be suitable for notebook computer, product line maintenance, be used easily on business.
- Dimensions (mm):205(L) x120(W) x35(H), be carried easily.
- High performance, 250MS/s real-time sampling, 20MHz-80MHz bandwidth.
- Operating System: Windows 7, Windows NT, Windows 2000, Windows XP, VISTA.
- 23 measurement functions, PASS/FAIL Check, be suitable for technical application.
- Waveform average, persistence, intensity, invert, addition, subtraction, multiplication, division, X-Y plot.
- Save waveform in the following: text file, jpg/bmp graphic file, MS excel/word file.
- FFT
- One computer can connect many DSO, extend channel easily.
- Labview\VB\VC\Delphi\C++Builder Second Design instance.
Pictures
Model
Hantek6082BE
Hantek6052BE
Hantek6022BE
Channel
2 Channels
Bandwidth
80MHz
50MHz
20MHz
Input Impedance
1MΩ 25pF
Max. Sample rate
250MS/s
150MS/s
48MS/s
Coupling
AC/DC/GND
Vertical resolution
8Bit
Gain range
10mV-5V, 9Steps
DC accuracy
±3%
Timebase range
4ns-1h, 38 Steps
4ns-5ks
Vertical adjustable
Yes
Input protection
Diode clamping
X-Y
Yes
EXT. input
Yes
No
Trigger Mode
Auto, Normal and Single
Trigger Slope
+/-
Trigger level adjustable
Yes
Trigger Type
Rising edge, falling edge
Trigger Source
CH1, CH2, EXT
CH1, CH2
Pre/Post trigger
0-100%
Buffer size
10K-64KB/Channel
1M
Sampling selection
Yes
Waveform Display
port/line, waveform average, persistence, intensity
Network
Open/Close
Vertical mode
CH1, CH2, Dual, ADD
Cursor measurement
Yes
Math
FFT, addition, subtraction, multiplication, division.
Cursor
Frequency, Voltage
Accessories
S/W CD, probes, manual, USB cord
Number | Attachments Title | Operating |
---|---|---|
1 | Hantek6082 Software | Download |
2 | Hantek6082 Driver | Download |
3 | Hantek6082 SDK | Download |
4 | Hantek6082 Manual | Download |
5 | Hantek6052 Software | Download |
6 | Hantek6052 Driver | Download |
7 | Hantek6052 SDK | Download |
8 | Hantek6052 Manual | Download |
9 | Hantek6022 Software | Download |
10 | Hantek6022 Driver | Download |
11 | Hantek6022 SDK | Download |
12 | Hantek6022 Manual | Download |
13 | Hantek6102 Software | Download |
14 | Hantek6102 Driver | Download |
15 | Hantek6102 SDK | Download |
16 | Hantek6102 Manual | Download |
17 | Hantek6212 Software | Download |
18 | Hantek6212 Driver | Download |
19 | Hantek6212 SDK | Download |
20 | Hantek6212 Manual | Download |